Failed Drive Replacement Ticket Note: What to Document After a Drive Swap

A drive swap takes five minutes. The ticket note after it decides whether the next person trusts the array. "Replaced bad drive, array rebuilding" is the note everyone writes and nobody can act on: which drive, which slot, which serial went to the vendor, and did the rebuild actually finish? Without those answers, the RMA stalls, the failed drive becomes a data-classification loose end, and the next tech reopens the same ticket when a second fault appears. This is the note that closes a drive swap for good.

Before you pull the drive: capture the fault evidence

The swap itself: what goes in the ticket

  1. New drive identity. Model, capacity, firmware, serial number of the replacement. Confirm capacity and firmware compatibility with the array before closing the bezel.
  2. Hot-swap or power-down. Record whether the swap was hot or required a shutdown — a cold swap on a running array is a different risk and a different audit trail.
  3. Rebuild/resync result. Record the rebuild start time, the completion time, and the final array state (OPTIMAL/HEALTHY) with the verification output pasted in. Close on "array optimal, verified at HH:MM" — never on "rebuild started."
  4. Post-swap checks. Controller confirms no new errors, OS sees the full capacity, application-level check (e.g., database or filesystem verification) passes if the procedure calls for one.
  5. Failed-drive disposition. RMA number and return tracking if it's going back to the vendor, or the destruction method and certificate if it holds sensitive data. A failed drive without a disposition is a compliance incident sitting in a parts bin.

A drive-replacement ticket note that closes cleanly

Drive swap: db05 (Dell R740, PERC H740P, VD0 data).
Fault: slot 4, bay 2 — predictive failure, SMART threshold
exceeded, controller log 09:12 "PDR 4 predictive failure".
Old: Seagate ST12000NM0127 12TB, FW SN02, SN ZLA4T2KX (photo
of amber LED on file). Array state: DEGRADED since 09:05.
New: same model/cap, FW SN03, SN ZLA9R1QW. Hot swap 09:40.
Rebuild: started 09:42, completed 13:17, array OPTIMAL —
storcli output verified 13:20, no media errors post-rebuild.
Failed drive: RMA #RX-88124 filed, return tracking TRK-5540217788,
shipped in anti-static + RMA box 14:05. Monitoring cleared.